DCU7 Full Digital Color Doppler Ultrasound Scanner
1. System Application
The DCU2 Full Digital Color Doppler Ultrasound Scanner excels in diagnosing abdomen (including GYN and OB), cardiology, vessels, and small parts. It employs advanced scanning modes: 2D, CFM, PDI, PW, and M, ensuring top-tier resolution and sensitivity.
Supports a variety of probes, including convex, linear, and transvaginal probes.
2. General Specification
2.1 Dimension
Main unit size: 660mm(H) x 500mm(W) x 1200-1400mm(H); height of liquid crystal holder is adjustable.
Net Weight: 35 Kg (without probe)
2.2 Power Supply
Dual Power-Supply System:AC110/230V -15% ~ +10%(self-adaptive supply voltage) 60/50Hz ±1Hz
2.3 Display
15" High Definition & Flicker-Free Color Medical LCD Monitor
3. System Description
3.1 Probe Specification
Probe specification |
3.5MHz multi-frequency convex probe |
7.5MHz multi-frequency linear probe |
6.5MHz multi-frequency transvaginal probe |
Scanning angle |
60° |
/ |
135° |
elements |
80 |
80 |
80 |
frequency scope |
2.0MHz-5.0MHz |
6.0MHz-9.0MHz |
4.5MHz-9.0MHz |
4 multi-frequency |
2.0/2.5/3.5/5.0 |
6.0/6.5/7.5/9.0 |
4.5/5.5/6.5/7.5 |
Max scanning depth |
≥190mm |
≥60mm |
≥60mm |
Blind zone |
≤5mm |
≤3mm |
≤4mm |
3.2 Operating Mode
B, B/B,4B Mode
M,B/M Mode
CFM
PDI
PW
THI
4. Measurement / Calculation
4.1 General Measurement
B Mode measurements: distance, area (distance method, ellipse distance method, trace method), circumference (distance method, ellipse distance method, trace method), volume (two-axial method), angle, histogram, sectional view, stenosis rate (length stenosis rate, area stenosis rate), and depth.
M Mode measurements: depth, slope, heart rate, and circle.
D Mode measurements: velocity, heart rate, flow velocity, time acceleration, Pulse/Resistance Index, Max differential pressure, PG mean, ratio, stroke volume, and flow rate.
4.2 Gynecology Measurement and Analysis :Uterus, endometrium, ovary, cervix, follicle.
4.3 Obstetric Measurement and Analysis
BPD, CRL, GS, FL, HL, TAD, TTD, APTD, HC, AC, EDC, FT, LV, THD, TCD, OFD, GA, EFW, LMP, AFI, and calculates GA, EFW, EDD, and growth curve; various formulas from many countries.
4.4 Urology Measurement and AnalysisProstate volume, residual urine volume.
4.5 Cardiology Measurement and Analysis
4.6 Measurement Report
Obstetric Measurement Report,
Gynecology Measurement Report,
Cardiology Measurement Report,
Urology Measurement Report and other measurement reports.
Automatically store measurement results and generate reports.rt
Standard configuration:
Main unit:1 pc |
Double probe sockets, automatically identify probe; |
3.5MHz multi-frequency abdomen convex probe:1pc |
7.5MHz multi-frequency high linear probe:1pc |
CD: 1pc |
Reticle: 1pc |
Optional configuration:
Video Printer(sony 897-MD) |