DCU7 Full Digital Color Doppler Ultrasound scanner
1.System Application
DCU2 full digital color Doppler ultrasound scanner is available for the diagnosis of abdomen (including GYN and OB), cardiology, vessel and small parts, with the following scanning mode: 2D, CFM, PDI, PW and M to provide the best resolution and sensitivity.
Support convex probe, linear probe and transvaginal probe, etc.
2.General Specification
2.1 Dimension
Main unit size: 660mm(H) x 500mm(W) x 1200-1400mm(H) (height of liquid crystal holder is adjustable)
N.W.: 35 Kg(without probe)
2.2Power Supply
Dual power-supply system: AC110/230V -15%~+10%(self-adaptation supply voltage ) 60/50Hz±1Hz
2.3Display
15" high definition & flicker-free color medical LCD monitor
3.System Description
3.1 Probe specification
Probe specification |
3.5MHz multi-frequency convex probe |
7.5MHz multi-frequency linear probe |
6.5MHz multi-frequency transvaginal probe |
Scanning angle |
60° |
/ |
135° |
elements |
80 |
80 |
80 |
frequency scope |
2.0MHz-5.0MHz |
6.0MHz-9.0MHz |
4.5MHz-9.0MHz |
4 multi-frequency |
2.0/2.5/3.5/5.0 |
6.0/6.5/7.5/9.0 |
4.5/5.5/6.5/7.5 |
Max scanning depth |
≥190mm |
≥60mm |
≥60mm |
Blind zone |
≤5mm |
≤3mm |
≤4mm |
3.2 Operating mode
B, B/B,4B mode
M,B/M mode
CFM
PDI
PW
THI
4. Measurement / Calculation
4.1 General measurement
B Mode measurement: distance, area (distance measurement method, ellipse distance method, trace method), circumference (distance measurement method, ellipse distance method, trace method), volume (two-axial method), angle, histogram, sectional view, stenosis rate (length stenosis rate, area stenosis rate) and depth.
M mode measurement: depth, slope, heart rate, circle
D mode measurement: velocity, heart rate, flow velocity, time acceleration, Pulse/Resistance Index, Max differential pressure, PG mean, ratio, stroke volume, flow rate.
4.2 Gynecology measurement and analysis :uterus, endometrium, ovary, cervix, follicle.
4.3 Obstetric measurement and analysis
BPD, CRL, GS, FL, HL, TAD, TTD, APTD, HC, AC, EDC, FT, LV, THD, TCD, OFD, GA, EFW, LMP, AFI, and calculate GA, EFW, EDD, and growth curve, different formula of many countries.
4.4 Urology measurement and analysisProstate volume, Residual Urine Volume
4.5 Cardiology measurement and analysis
4.6 Measurement report:
Obstetric measurement report,
gynecology measurement report,
cardiology measurement report,
urology measurement report and other measurement reports
Automatically store measurement results and generate reportrt
Standard configuration:
Main unit:1 pc |
Double probe sockets, automatically identify probe; |
3.5MHz multi-frequency abdomen convex probe:1pc |
7.5MHz multi-frequency high linear probe:1pc |
CD: 1pc |
Reticle: 1pc |
Optional configuration:
Video Printer(sony 897-MD) |
6.5MHz multi-frequency trans-vaginal prob |